Ten suppliers that publish a BAL 40 position for Australian windows — ranked on the test evidence and the conditions attached to the claim, not on how confidently the claim is worded.

Which suppliers in Australia publish a BAL 40 window position?

Ten Australian suppliers publish a BAL 40 window position, but only a few publish the test evidence behind it. The list below separates framing systems, finished-window fabricators and one louvre specialist, and states for each what is published, what condition the BAL 40 claim depends on, and what a specifier still has to confirm in writing.

A BAL 40 elevation is not a product upgrade. It is a compliance argument that has to survive a certifier, and the argument is made of three parts: a tested window system, the screen or shutter that the test assumed, and the glass make-up inside the frame. Any one of those parts going missing turns a rated product into an unrated installation, which is why this list ranks suppliers on what they publish about all three rather than on the single word "certified".

The search that brings most specifiers here is bal40 windows, and it usually arrives with a council planning permit already issued. That matters, because the BAL number on the permit is fixed: it comes from the site's vegetation class, effective slope and distance to the fire front, and it cannot be negotiated down by choosing a better window. What can be negotiated is who supplies the evidence, and whether the evidence covers the exact configuration being installed. The background to that assessment is covered in ROPO's guide to windows and doors in bushfire prone areas, which is the place to start if the permit has arrived but the specification has not.

Every entry below manufactures or supplies into the Australian market, and every one of them publishes a bushfire position on a page a buyer can open. What separates them is the depth of that publication. One publishes a BAL-FZ solution tested without shutters. One publishes a clause-by-clause reading of AS 3959-2018 with its test reports attached. Several publish per-product rating tables. One publishes only a requirement matrix. The order reflects that difference, because on a BAL-40 job the depth of the evidence is the product. For buyers starting from the product side, the aluminium windows for Australian projects range is the relevant catalogue; this article stays with the compliance question.

How this BAL 40 list was built

The method is deliberately narrow, because a bushfire ranking that mixes marketing with evidence is worse than no ranking at all. Every entry had to satisfy one test before it was considered: the company must publish, on its own website, a statement that a named product or system achieves a stated BAL, or a statement that defines the conditions under which its products satisfy AS 3959. Companies that only publish an explainer about BAL levels, with no product position, were excluded — Southern Star, Nuline, Bradnam's, Stegbar and Jason Windows all fall into that group and are recorded as not publishing.

Once a company passed that test, the order was set by three things: the ceiling it publishes (BAL-FZ outranks BAL-40), the specificity of the evidence (a test report number outranks a headline), and the completeness of the condition (a supplier that states the screen requirement is more useful than one that omits it). Nothing in the order depends on revenue, staff numbers, plant capacity, market share or price, because none of those are published in a form a specifier can verify. A ranking built on unverifiable size is a ranking of marketing budgets.

The evidence for each entry was taken from the company's own pages in November 2026, quoted verbatim, and checked against the page it came from. Where a claim depended on a document rather than a web page — a product guide PDF, a certificate PDF — the document is cited. Where a company publishes nothing on a point, the entry says so rather than filling the gap. That rule cuts both ways: ROPO appears in this article as the publisher, but its own BAL position is stated in the same language as everyone else's, including the part it cannot yet evidence.

Why a published test standard outranks a published adjective

Every company on this list calls itself a leader in bushfire performance. The useful question is which standard the claim rests on, and there are three that matter. AS 3959-2018 is the construction standard: it sets what a building at a given BAL must do, including how openings are protected. AS 1530.8.1 is the test method: it exposes a specimen to radiant heat and, at the higher levels, to flame, and records whether the element fails. AS 2047 is the window performance standard that still applies alongside both, covering structural performance, water penetration, air infiltration and operating force.

A supplier that names AS 1530.8.1 and a test report number is telling you the specimen passed a fire test. A supplier that names only AS 2047 is telling you the window performs structurally, which is necessary but not the bushfire argument. Both matter, and a BAL-40 specification normally needs both — which is why the entries below distinguish them rather than treating "certified" as a single condition, and why the suppliers that rank highest for bal40 windows are the ones that name a report rather than a logo. The verification method for the AS 2047 half is set out in the guide to verifying AS 2047 certified windows, and the certificate itself is published as the AS 2047-2014 certificate.

What was excluded, and why it matters to the ranking

Five companies with strong general reputations were left out, and the reason is uniform: none of them publishes a product-level BAL position. Their sites discuss bushfire risk, or offer a bushfire-rated option in a form that cannot be verified from the public page, but a specifier cannot open a page and read which product achieves which level. That is not a criticism of the windows; it is a statement about the documentation. On a BAL-40 job, an unverifiable option is not an option, because the certifier will ask for the evidence and the answer has to be a document, not a phone call.

The same rule removed one company that publishes a bushfire page but no product rating: Southern Star's page explains AS 3959 and the six levels, then links to product ranges rather than stating a level. It is a useful explainer and a weak specification source, so it is recorded as not publishing. Two systems houses were kept in, AWS and Alspec, with the role stated explicitly, because a specifier often meets the BAL-40 claim at system level and the fabricator at contract level. Mixing the two roles without saying so is the most common way a bushfire specification falls apart between tender and site.

Which ten suppliers should a BAL 40 project shortlist?

The ten entries below are grouped by role rather than by size, because the first decision on a BAL-40 job is not which company but which part of the supply chain you are buying. A framing system is specified by an architect and built by a fabricator. A finished-window fabricator carries the warranty and the installation. A louvre specialist supplies a component into someone else's frame. A specifier who knows which of those they need can skip most of the list before pricing starts. The phrase bal40 windows is used across all three roles in the market, which is exactly why the roles have to be separated here.

These are ten entries, not ten interchangeable BAL-40 products. Two of them — Dowell and A&L — publish less than a per-product BAL-40 claim, and their entries say so rather than rounding up; they stay in because a specifier evaluating a shortlist needs to know where each supplier's published position actually stops. Each entry quotes what the company publishes, names the condition attached to the rating, and states the gap. Where a company ties its BAL-40 claim to a screened opening, the entry says so, because omitting that condition is the difference between a compliant installation and a failed inspection. No capacity, revenue, headcount, price or lead-time figure is attributed to any company, because none of them publish one in a form that could be checked. For the product side of the same question, the custom aluminium window range shows how a schedule is priced once the compliance route is fixed.

1. Paarhammer Windows & Doors — the only published BAL-FZ solution without shutters

Paarhammer states its position in one line: "Safety for all Bushfire Attack Levels (BAL's) including Flame Zone BAL-FZ without need for shutters." That sentence is the strongest single claim in this list, because BAL-FZ is the level at which most suppliers stop and require a shutter. The company then breaks the range down by level: "For BAL-12.5 and BAL-19 all Paarhammer Ranges and products are suitable", and "For BAL-29 choose from the Architectural Timber Range (made with bushfire safe timber and toughened glass) or the Wood-Alu Range", with dedicated BAL-40 and BAL-FZ product pages behind those links.

The construction behind the claim is published too: a frame made from self-extinguishing, FSC-certified Manilkara Bidentata, double glazing with special fire protection glazing, German hardware, and ember or flyscreens on all windows as per Australian Standard, with compliance certification supplied with the windows and doors. For a specifier, that is the shape of a bushfire system rather than a bushfire option: frame species, glazing make-up, screens and certification are described as one package. The gap is commercial and geographic: no service area, trade terms or price list are published, and the ranges are timber-based, so a project that needs an aluminium aesthetic or a fully recyclable frame is looking at a different supplier.

2. Miglas Windows — BAL-40 without external shutters, tested at a NATA laboratory

Miglas publishes the claim and the test history in the same paragraph: "Our AliClad system has been designed to be bushfire resistant for all attacks up to and including BAL-40, without needing external shutters." It then names the laboratory and the standards: "The Miglas AliClad system was the first fully tested range of bushfire windows and doors in Australia. Testing was conducted at the Exova Warrington Dandenong Victoria, a NATA-accredited laboratory and exceeded AS 1530.8.1-2007 to comply with the requirements of AS 3959-2009."

The company is equally direct about the ceiling. Asked whether its products can be used above BAL-40, it answers that they "are specifically certified for BAL-40 conditions" and that for BAL-FZ "all products should be certified to those conditions". That is the correct answer, and it is rarer than it should be. The system is a composite: a timber window with an aluminium exterior, double glazed, with the glazing element allowed to reach 6m² — over twice what the company says standard tested windows allow. The gap: no trade terms, service area or price list are published, and the product is a premium composite rather than a volume aluminium system, so the comparison with a project-grade aluminium quote is not like for like.

3. Alspec — BAL-40 framing with named test reports, per product

Alspec publishes the most granular evidence in this list, and it does it in the least readable format: a certificate PDF that names the test authority, the standard and a report number for each product. The opening sentence is explicit — "The following window & door products supplied by Alspec have been tested by an independent testing authority to AS1530.8.1 (BAL40) achieving a no failure result" — and the document then lists systems against report numbers, including McArthur, ProTilt, Swan, ASW44, ViewMax, AS85, Hunter Evo, Hawkesbury, ThermAFrame, ProVista, ecoFRAMEplus, AirflowPlus and Altitude.

The same document states the condition that specifiers most often miss: "The requirements under AS3959-2018 standard for screening of openable parts of 'windows' shall still apply to tested systems. Clause 3.8. Recommended material is stainless steel wire mesh." It also sets a minimum of 6mm toughened glass across the tested products, with pane-area limits per report. For a specifier, this is what good evidence looks like: a tested system, a stated screen requirement, and a glass minimum that can be written into the schedule. The gap is the role. Alspec supplies framing and screening systems, not finished windows, so the BAL-40 pack has to be built and warranted by a fabricator — and the fabricator's name, not Alspec's, is the one that ends up on the compliance statement.

RouteWho you contract withWho holds the BAL evidenceWho builds and warrants the unitWhere BAL-40 claims usually break
Systems houseLicensed fabricatorSystem supplier, per tested productFabricatorFabricator builds outside the tested configuration
Finished-window fabricatorFabricatorFabricator, on the tested rangeFabricatorScreen omitted from the order
Component specialistFabricator, who buys the componentComponent supplier, plus the fabricator's frame testFabricatorComponent tested in a different frame
Factory-direct importFactory, per scheduleFactory pack, checked against AS 1530.8.1Factory, installed by othersNo AS 1530.8.1 evidence behind the AS 2047 certificate

Read the last column first. Every route can deliver a compliant BAL-40 window; what differs is where the argument is weakest. On a systems route it is the fabricator's fidelity to the tested configuration. On a fabricator route it is whether the screen was ordered. On a component route it is whether the component was tested in the frame it is going into. On an import route it is whether the fire test exists at all, separate from the structural certificate. A specifier who names the weak point in the order documents has done most of the compliance work before a single quote arrives.

4. Architectural Window Systems (AWS) — BAL-40 at system level, built by licensees

AWS publishes its bushfire position at the top of a dedicated page: "AUSTRALIA'S LARGEST RANGE OF BAL40 BUSHFIRE RATED WINDOWS AND DOORS", headed "BUSHFIRE RATED SYSTEMS BY DAWS". The company is a systems house in the strict sense: it designs and tests systems, and the windows are built by its licensed fabricator network, which is why a specifier meets the BAL-40 claim at system level and the contract at fabricator level. The system families a specification usually names — Vantage, Elevate and ThermalHEART — are AWS designs.

For an architect, that is the right place for a BAL-40 claim to live, because the tested specimen, the frame depth and the drainage detail all trace back to the system owner. The entry sits fourth rather than first for a documentation reason: the public bushfire page carries the headline claim and little else, so the per-product BAL table and the test reports have to be obtained through the fabricator or the specifier portal. The gap is therefore the same as Alspec's, with one addition — the specifier needs to confirm not only that the system is rated but that the specific fabricator is licensed for that system and builds to the tested configuration.

5. Trend Windows & Doors — per-product BAL-40 tables across four ranges

Trend publishes the most usable table in this list for a builder, because it lists products against ratings rather than systems against adjectives. The Botanica timber range shows awning, casement, sliding and fixed windows at BAL40 in both meranti and cedar, with double hung, sashless and louvre windows at BAL19 "deemed to satisfy (400mm above ground)". The Synergy and Quantum aluminium ranges show awning, sliding, fixed, bay and custom windows at BAL40, with Quantum louvres at BAL29 unless fitted with an Invisiguard or equivalent screen, in which case BAL40 applies.

The company also states the caveat that most tables leave out: "in some instances to achieve these ratings screens, seals, glass and hardware may need to be optimised/added." That sentence is the difference between a rating and an order. A builder who quotes a Quantum hinged door at BAL40 without reading the note will miss that the rating applies to an open-out door, or to an open-in door only with an aluminium or stainless steel screen in an aluminium frame. The gap is service coverage and commercial terms: the enquiry form states "We are unable to service this area (WA/NT)", and no trade price list or account terms are published.

6. Wideline — BAL-40 aluminium and BAL-29 timber, supply only

Wideline states both limits in one answer: "Wideline has designed a range of aluminium windows and doors that are certified to meet the requirements bushfire prone zone up to BAL-40, and timber windows and doors up to BAL-29." For a specifier weighing aluminium against timber on a bushfire site, that single sentence resolves the question: the aluminium range carries the higher level, the timber range stops one level lower.

The supply model is stated just as plainly: "We are a supply only company and we do not come out to your property to measure and quote." Distribution runs through New South Wales, with Victorian distributors covering Melbourne and the Latrobe Valley. For a builder, supply-only is usually the desired arrangement on a bushfire job, because the measure and the installation stay under the builder's control and the BAL evidence travels with the units. The gap is the same as its peers: no trade price list, no minimum order and no distributor terms are published, and the BAL-40 claim is not tied on the page to a named test report, so the certificate has to be requested.

7. Dowell Windows — a published attack-level range and a timber ceiling

Dowell publishes its bushfire position in its product guides rather than on a web page, which is typical of a manufacturer with a long branch history. The timber guide states its ceiling without hedging: "All Dowell timber products are rated to BAL 19." That is a clear, low number, and for a BAL-40 project it removes the timber option from the rated elevation rather than leaving it ambiguous — which is more useful than a page that implies a rating without stating one.

The value of this entry is the branch network: Dowell publishes showrooms and manufacturing locations across Victoria, New South Wales, Queensland, South Australia, Tasmania, the ACT and Western Australia, which matters when a bushfire job needs a site visit or a replacement after handover. The gap is documentation depth on aluminium. The aluminium product guide is published as a downloadable PDF from the same site, but the per-range BAL limit is not stated on the product pages and no test report is linked, so a specifier should ask for the report number and the screen condition before writing an aluminium range into a BAL-40 schedule. Until that document arrives, treat the range as a candidate rather than a compliant product.

8. Alvision (Carinya) — a named BAL-40 range with an AS 1530.8.1 result

Alvision publishes a dedicated page for the Carinya BAL40 range, and the claim is specific enough to be useful: "The Carinya BAL40 range successfully exceeded system test requirements outlined in AS1530.8.1 while remaining in operation after the test." The company also explains why post-test operation matters — egress and access for occupants or fire authorities — which is a detail most suppliers leave out, because most tests stop at "no failure" rather than at "still operable".

The range is listed product by product: Classic sliding, Classic high performance sliding, Classic awning, Classic sliding and stacking door, Classic fixedlite, Select hinge door, Select double hung and fall prevention KidScreens, with a compliance label on every unit to assist certification on site. For a Queensland project, that combination — a named range, a named range of products, and a label — is close to what a certifier wants to see. The gap is scale and coverage: the page publishes a Caboolture address rather than a national service network, and no trade terms, price list or installation policy are published, so the range is a specification answer rather than a supply answer outside south-east Queensland.

9. Breezway — the louvre specialist that publishes its AS 3959-2018 reading

Breezway sells a component, not a finished window, and its bushfire page is the most technical document in this list. It opens by stating the basis: "The following requirements for using Altair Louvre Windows in bushfire prone areas are based on our interpretation of AS3959-2018 'Construction of Buildings in Bushfire Prone Areas' and bushfire test reports." It then walks through each level with the requirements that apply: at BAL-12.5 and BAL-19, toughened glass within 400mm of the ground or a structure, external screening in corrosion-resistant steel, bronze or aluminium mesh with a maximum aperture of 2mm and gaps no greater than 3mm; at BAL-29 and BAL-40, Altair louvres within the Easyscreen system, toughened glass, and at BAL-40 a 6mm minimum for fixed lites with a flammability index above 5 for the glazing wedge.

It also draws the line at the top: "Bushfire Attack Level FZ: Louvre Windows are to be completely protected by compliant bushfire shutters", and it publishes the BAL-29 and BAL-40 test reports plus a Warrington Fire equivalency report. For a specifier, this is the standard to hold other suppliers to: a published interpretation, a clause-level requirement, and the test reports attached. The gap is structural rather than documentary — Breezway makes louvres, so the BAL-40 outcome depends on the fabricator who builds the frame, and the company says so: "Breezway solely manufactures however our louvres are available to buy through a highly qualified network of window fabricators."

10. A&L Windows — a published BAL requirement matrix, without a per-product tested level

A&L publishes a bushfire page that does something different from the rest of this list: instead of claiming a level per product, it publishes the requirement per level and leaves the product column to the buyer. At BAL40 the table states "Steel Mesh Screens required to window openings", against BAL12.5, BAL19 and BAL29 where aluminium mesh screens are required. The product list under the matrix covers sliding, awning, fixed, double hung, louvre and Boutique windows, sliding, French and Boutique sliding doors, bifold windows and doors, and aluminium door frames.

That layout is honest but incomplete. It tells a builder what the opening has to have at BAL40 and which products the company makes, but it does not publish a per-product tested BAL, and the matrix cells themselves carry the screen requirement rather than a rating. For a specifier that means one extra step: confirm in writing that the specific product and screen combination has been tested to the level required, and get the report number. The company's service footprint and trade terms are not published on that page either, although the enquiry form captures a builder licence number and an estimated builds-per-year figure, which is the shape of a trade relationship rather than a retail one.

#SupplierRolePublished BAL ceilingPublished evidencePublished condition or gap
1Paarhammer Windows & DoorsFinished-window fabricator (timber / wood-alu)BAL-FZ without shuttersLevel-by-level product pages, compliance certification suppliedNo service area, trade terms or price list published
2Miglas WindowsFinished-window fabricator (composite)BAL-40 without external shuttersAS 1530.8.1-2007 exceeded, NATA laboratory namedNo trade terms or service area published; not BAL-FZ
3AlspecFraming and screening systemsBAL-40AS 1530.8.1 test reports per product, certificate PDFScreening still required under AS 3959-2018; fabricator warrants the unit
4AWSFraming systemsBAL-40System-level bushfire page; reports via fabricator or portalPer-product table and test reports not on the public page
5Trend Windows & DoorsFinished-window fabricatorBAL-40 (BAL-29 on one accessible door)Product-by-product tables across four rangesScreens, seals, glass and hardware may need upgrading; no WA/NT service
6WidelineFinished-window fabricator, supply onlyBAL-40 aluminium; BAL-29 timberPublished statement by materialNo test report linked; no trade terms published
7Dowell WindowsFinished-window fabricator, branch networkBAL 19 timber; no BAL limit stated for aluminiumProduct guides published as PDFsAluminium limit and test report not on product pages
8Alvision (Carinya)Finished-window fabricator (QLD)BAL-40AS 1530.8.1 exceeded, remains operable, labelled per unitSingle-state footprint; no trade terms published
9BreezwayLouvre component and systemBAL-40 (BAL-FZ with shutters)Clause-level AS 3959-2018 reading, BAL-29 and BAL-40 reportsMust be built by a licensed fabricator; not a finished window
10A&L WindowsFinished-window fabricatorBAL-40 requirements matrixRequirement table by levelNo per-product tested level or report published

The table is a map of published positions, not a price league. Two specifiers reading it will reach different shortlists, and both can be right: a Macedon Ranges project with a flame-zone edge keeps the first two entries and drops the rest, while a south-east Queensland estate at BAL-40 keeps the fabricators and treats the two systems houses as a route rather than a supplier. What the table guarantees is narrower and more useful: every row is a statement the company makes about itself, on a page a buyer can open, and every condition that the statement depends on is named next to it.

Why no factory-direct importer is ranked in this list

An imported window can be specified on a BAL-40 elevation, but only on evidence, and the evidence is not the same document as the one that gets an Australian project through its structural review. ROPO publishes AS 2047-2014 for windows and doors, AS 1288 for glass selection, NZS 4211 through CodeMark for New Zealand and Miami-Dade for hurricane markets — a compliance set that covers structure, water, air and impact, and none of which is an AS 1530.8.1 bushfire test. On a BAL-40 elevation the missing document is exactly the one that matters, so ROPO is not ranked here, and a specifier who wants the import route should ask any factory for three things before a deposit: the AS 1530.8.1 report covering the frame, glass and screen combination; the screen system and its fixing detail; and a named party who will convert the overseas evidence into the compliance statement the certifier receives.

That is a harder standard than most factories can meet today, and it is the honest one. Where an import route does work on a bushfire site is on the elevations that are not BAL-rated — the leeward side of the same house, a shed, a boundary wall of glazing — and on projects where the BAL-40 openings are small enough to be bought from a local fabricator while the bulk of the schedule comes from the factory. The aluminium windows built to a schedule range and the Australian purchasing process page set out how that split is normally handled, and the local Australian partners are the usual route for the installation and rectification side.

A completed courtyard elevation with full-height sliding and bifold units. On a BAL-40 site the glazing area is the exposure, so the units and the screens over them have to be specified as one system.
A completed courtyard elevation with full-height sliding and bifold units. On a BAL-40 site the glazing area is the exposure, so the units and the screens over them have to be specified as one system.

What does BAL 40 require of a window under AS 3959?

BAL 40 sits one level below the flame zone and it is the level at which the specification stops being about embers and starts being about radiant heat and the possibility of flame contact. AS 3959-2018 sets the construction requirements for each level, and for openings it does so through a combination of glass, screening and frame requirements rather than through a single product approval. That structure is why a window can be "BAL 40 rated" and still fail an inspection: the rating describes a tested assembly, and the assembly includes the screen.

For a supplier comparison, the practical reading is that a BAL-40 window is a system of four parts — frame, glass, screen or shutter, and the fixing detail that holds the screen to the frame. The entries in this list differ mainly in how much of that system they publish. The sections below set out what each part has to deliver, using the published readings of AS 3959-2018 from suppliers who document their interpretation, so a specifier can hold every quote against the same checklist. The phrase bal40 windows is used in the market to describe everything from a toughened pane to a fully screened assembly, and the gap between those two meanings is where most of the risk sits.

The six BAL levels, and what changes at BAL 40

The six levels run from BAL-LOW to BAL-FZ, and each one describes a predicted exposure rather than a construction method. BAL-LOW carries insufficient risk to warrant specific construction requirements. BAL-12.5 is ember attack. BAL-19 adds burning debris and heat flux between 12.5 and 19 kW/m². BAL-29 raises that band to 19 to 29 kW/m². BAL-40 raises it again to 29 to 40 kW/m² and adds "increased likelihood of exposure to flames", which is the wording A&L and Trend both publish from the same source material. BAL-FZ is direct exposure to flames from the fire front with heat flux above 40 kW/m².

What changes at BAL-40 is not only the number. The screen specification tightens, the glass minimum rises, the frame has to hold both under a heat load, and the acceptable product list narrows — which is why several suppliers in this list publish BAL-40 for some products and stop at BAL-29 for others. A double hung window that is "deemed to satisfy" at BAL-19 because it sits 400mm above the ground does not carry that concession at BAL-40, and a louvre that passes at BAL-29 needs a specific screen system to reach BAL-40.

LevelPredicted exposureWhat it means for a windowWhere suppliers usually stop
BAL-LOWInsufficient risk to warrant specific construction requirementsStandard AS 2047 window, no bushfire measuresNot a constraint
BAL-12.5Ember attackScreen the openings, toughen glass near the ground or structuresRarely a constraint
BAL-19Ember attack plus burning debris, 12.5–19 kW/m²Screen specification and glass rules tighten; some products deemed to satisfy above 400mmTimber ranges often stop here
BAL-2919–29 kW/m² with increasing ember loadSpecific screen systems, toughened glass, frame support for the screenLouvres without a tested screen system
BAL-4029–40 kW/m² with increased likelihood of flame exposureTested assembly, 6mm toughened minimum in tested products, steel mesh screens, metal-supported framingMost of the market: this is the common ceiling
BAL-FZDirect flame exposure above 40 kW/m²Shutters, or a specifically tested system that operates without themAll but one supplier in this list

The table is a summary of published positions, not a substitute for the standard. What it shows is where the market's ceiling sits: BAL-40 is the highest level at which a mainstream Australian window range is routinely published, and BAL-FZ is a specialist segment with two answers — a shutter, or a tested system that does not need one. A specifier whose permit says BAL-40 is therefore working at the edge of the standard product range, which is why the documentation matters more here than at any other level.

Why the screen is part of the window, not an accessory

The single most common BAL-40 failure is a window supplied without the screen the test assumed, or with a screen that does not match the tested specification. AS 3959-2018 treats the protection of openings as part of the construction requirement, and the suppliers who document their reading are explicit about it. Breezway publishes the requirement as a list: external screening in corrosion-resistant steel, bronze or aluminium mesh, a maximum aperture of 2mm, gaps between screen and frame no greater than 3mm, and the mesh or perforated screen "completely supported by framing made of metal or bushfire resistant timber".

Alspec makes the same point from the testing side: even where a system has passed AS 1530.8.1 at BAL40, "the requirements under AS3959-2018 standard for screening of openable parts of 'windows' shall still apply to tested systems", with stainless steel wire mesh recommended. A tested window without its screen is not a BAL-40 window; it is a tested window in a BAL-40 opening, which is a different and non-compliant thing. A&L's matrix states the same condition at the product level: at BAL40, "Steel Mesh Screens required to window openings", where the lower levels accept aluminium mesh.

ElementWhat the published AS 3959-2018 readings require at BAL-40Published byWhat goes wrong on site
Screen materialCorrosion-resistant steel mesh, or stainless steel wire mesh where a tested system is usedBreezway, Alspec, A&LAluminium flyscreen substituted for steel mesh
Screen apertureMaximum 2mm, entire opening screened when the sash is openBreezwayStandard insect mesh with a larger aperture
Screen gapsNo gap greater than 3mm between screen and frameBreezwayScreen fixed to the reveal rather than the frame
Screen supportMesh supported by metal framing, or bushfire-resistant timberBreezwayTimber bead or plastic trim carrying the mesh
GlassToughened; 6mm minimum in tested BAL-40 products, with pane-area limitsBreezway, AlspecLaminated or annealed glass carried over from a lower level
Operable partsScreening applies to openable sashes and doors, not only fixed litesAlspec, A&LScreens priced as an optional extra and dropped at value engineering

Two operational consequences follow. The first is that the screen has to be ordered with the window, from the same supplier, so that the tested combination is the delivered combination. The second is that the screen becomes a maintenance item with a compliance function: a torn mesh or a missing clip is not a cosmetic defect on a BAL-40 elevation. Suppliers who publish the requirement also publish the maintenance obligation, and a builder who hands over a BAL-40 house should hand over the screen specification with it.

Glass: toughened, thickness and pane limits

Glass is where BAL-40 specifications most often drift, because the glass in a bushfire window is doing two jobs at once. It has to resist the heat load of the level, and it has to satisfy AS 1288 for safety glazing and structural selection. Breezway's published reading sets toughened glass at the lower levels with a minimum thickness that rises to 6mm for fixed lites at BAL-40, and requires the glazing wedge to carry a flammability index above 5. Alspec's certificate sets a minimum of 6mm toughened glass across its tested products and then caps the pane area per report, from 2.4m² on one report to 6.28m² on another depending on the make-up.

Those pane limits are the part a designer is most likely to break, because a BAL-40 elevation is often the one with the view. A 4m² fixed pane in a tested system may be compliant on one report and outside the tested area on another, and the difference is not visible on a drawing. The practical rule is to specify glass by make-up and pane area together, and to have the supplier confirm both against the report before the frame is ordered. The options across a standard range are set out in ROPO's glass options page, and the way glass performance is expressed is explained in the guide to window U-value — useful on a bushfire job, because the same make-up has to satisfy the energy rating as well as the fire requirement.

Frames, seals and the hardware interface

The frame carries the screen and the glass, so its material and its fixing detail are part of the bushfire argument rather than a finish choice. Paarhammer publishes its frame species for exactly this reason: a self-extinguishing, FSC-certified hardwood, with the glazing and the screens described as part of the same range. Alspec's tested products are aluminium systems with a stainless steel mesh screen, and the report numbers are per system rather than per material family. The common thread is that the frame has to be capable of holding a metal screen under load without relying on a timber bead or a plastic trim.

Hardware matters because it is the interface between the operable part and the screen. A multi-point lock strip that fouls a screen frame will be left off, and a window left off is a window that does not close. The tested configurations published by suppliers assume the hardware specified with the system, which is why a substitute handle or a different lock can take a unit outside its tested scope even when the frame and glass are unchanged. The hardware range behind a custom order is the place to check what is being fitted, and the factory's quality and certification page shows how the evidence is assembled for a project pack.

Where the certificate and the test report diverge

A certificate and a test report answer different questions. The certificate says a product or system has been assessed and meets a standard within a stated scope. The test report says what happened to a specific specimen on a specific day, at a specific size, with a specific glass make-up and a specific screen. On a BAL-40 job, the certificate is what the certifier files and the report is what the builder needs, because the report is the only document that can confirm the configuration on the drawing is the configuration that was tested.

The divergence becomes a real risk when the scope of a certificate is broader than the tested configurations behind it, or when a certificate is carried across from another market. ROPO's own position is a clear example: its published certification covers AS 2047-2014, AS 1288, NZS 4211 through CodeMark and Miami-Dade, and none of those is an AS 1530.8.1 bushfire test, so its windows are not presented here as BAL-40 products. A supplier that cannot separate its structural certificate from its fire evidence is telling you something about how carefully the rest of the order will be documented.

An open-plan living elevation opening to a terrace. Replacing a standard slider with a screened, toughened unit at BAL-40 changes the frame depth, the track and the head detail, not only the glass.
An open-plan living elevation opening to a terrace. Replacing a standard slider with a screened, toughened unit at BAL-40 changes the frame depth, the track and the head detail, not only the glass.

How does BAL 40 differ from BAL 29 and BAL FZ?

The three levels are often treated as a ladder, but the difference between them is not a single increment. BAL-29 and BAL-40 both assume ember attack and radiant heat, and the step between them is the likelihood of flame exposure and a higher heat flux band. BAL-FZ assumes direct flame contact. Each step changes the acceptable assembly, and at BAL-FZ it changes the strategy: protection moves from the window to a shutter in front of it, unless a supplier has tested a system that works without one.

For a specifier, the useful question is not "what is the difference in degrees" but "what has to change in my schedule". Going from BAL-29 to BAL-40 usually changes the screen material, the glass thickness and the product list. Going from BAL-40 to BAL-FZ changes the whole approach. The sections below set out what changes at each step, using the published positions of the suppliers in this list, so the comparison can be made against documents rather than against descriptions of fire behaviour. Buyers comparing bal40 windows with BAL-29 alternatives are usually trying to answer one cost question, and the honest answer is that the saving is in the screen and the glass, not in the frame.

BAL 29 to BAL 40: what actually changes on site

In most published product tables, the frame stays the same and the screen changes. Trend's tables show louvres at BAL29 unless fitted with an Invisiguard or equivalent screen, in which case BAL40 applies to the same product. Wideline publishes BAL-40 for aluminium and BAL-29 for timber, which is a material step rather than a product step. A&L's matrix moves from aluminium mesh screens at BAL12.5, 19 and 29 to steel mesh screens at BAL40, on the same product list. Breezway's reading raises the fixed-lite glass minimum to 6mm at BAL-40 and requires the Easyscreen system for louvres at both BAL-29 and BAL-40.

What that means on site is that the upgrade is usually procured as a screen and glass change, which is good news for the budget and bad news for the paperwork, because the frame already on order may not have been tested with the upgraded screen. A builder who upgrades the specification mid-project without re-checking the test scope can end up with a BAL-40 screen on a BAL-29 tested frame. The change has to go through the supplier as a configuration change, not through the site as a substitution.

BAL FZ: the shutter question

At BAL-FZ the market splits cleanly. Most suppliers require a compliant bushfire shutter, and say so: Breezway states that at BAL-FZ "Louvre Windows are to be completely protected by compliant bushfire shutters". Others simply do not publish a BAL-FZ product. One supplier in this list publishes a tested alternative: Paarhammer's "Safety for all Bushfire Attack Levels (BAL's) including Flame Zone BAL-FZ without need for shutters", supported by its own FAQ statement that its BAL-FZ compliant windows and doors "have been tested and approved for use without shutter".

For a project on a flame-zone boundary, that difference is decisive, because a shutter changes the architecture: it needs a head detail, a clearance, a power or manual mechanism, and a maintenance regime. Where a tested no-shutter system is available, the window stays a window. Where it is not, the shutter is part of the building envelope and should be specified by the architect rather than added by the window supplier at the end of the programme.

BAL 40 and bushfire-resistant timber

Timber is not excluded at BAL-40, but the species and the treatment become part of the specification. Paarhammer publishes a self-extinguishing hardwood frame for its BAL-40 and BAL-FZ ranges. Trend publishes Botanica timber windows at BAL40 in both meranti and cedar for awning, casement, sliding and fixed products, while its double hung, sashless and louvre timber products stop at BAL19 with a 400mm height concession. Wideline publishes timber to BAL-29 and aluminium to BAL-40. Dowell publishes all its timber products at BAL 19.

Read together, those positions describe a market in which timber can reach BAL-40 for fixed and simple operable products, and generally stops lower for products with more moving parts or more exposed edges. A designer who wants a timber aesthetic on a BAL-40 elevation should therefore expect to specify fixed and awning products in timber and to solve the doors in aluminium, or to move to a specialist timber system. Neither answer is wrong; the mistake is to assume a timber range that carries BAL-40 on one product carries it across the range.

BAL 40 is not a fire rating: what it does not cover

BAL-40 describes resistance to a bushfire attack on the exterior of a building. It is not a fire-resistance level, it does not describe how long a window resists a fire inside the building, and it does not replace the fire-separation requirements that apply to boundary walls, car parks or commercial buildings. A window specified as BAL-40 is not thereby a fire-rated window in the NCC sense, and a specification that conflates the two will fail at the first review.

The distinction matters commercially because "fire rated windows" is a search term that pulls in both markets. A BAL-40 buyer needs AS 3959 and AS 1530.8.1 evidence. A fire-rated buyer needs the relevant fire-resistance level evidence for the element. Some products carry both; most carry one. The cleanest way to keep them apart is to write the standard into the schedule rather than the adjective, which is also the fastest way to see which suppliers can answer.

What should a buyer ask a BAL 40 supplier before signing?

Most BAL-40 disputes are not about whether the window was rated; they are about which configuration was rated and whether the delivered unit matched it. A buyer who asks five questions in writing before the deposit removes most of that risk, and the answers double as the compliance pack the certifier will ask for later. The questions below are ordered by how often they expose a gap: the first two catch most of the problems, and the last three are the ones suppliers answer least readily because the answer requires a document rather than a sentence.

None of the ten suppliers in this list publishes all five answers on its website, and that is not a criticism of any of them; trade documentation in this market is issued per project rather than published. What a buyer controls is the sequence. Ask in writing, keep the replies, and attach them to the purchase order so the specification that was priced is the specification that is built. Buyers evaluating bal40 windows across several suppliers should use the same question list for each, because comparable answers are worth more than persuasive ones.

Seven questions that produce documents, not adjectives

The first question is which standard the BAL claim rests on, and the answer should name AS 1530.8.1 and a report number. The second is the tested specimen: frame system, glass make-up, screen product and hardware family, described precisely enough to compare with the schedule. The third is the screen — whether it is included in the tested configuration, and if the rating depends on it, what happens to the price and the compliance if the screen is deleted. The fourth is the pane limit, because a tested system usually caps glass area per pane and per report, and a large fixed pane may sit outside it.

The fifth is the certificate's scope: which products and which configurations it covers, and whether the fabricator building the units is licensed under it. The sixth is the compliance statement that will travel with the delivery, and who signs it. The seventh is the rectification route — what happens when a unit arrives with a screen missing or a pane outside the tested area, and who pays for the remake. A supplier who answers all seven in writing is a better risk than one who answers with a brochure, regardless of where they sit in this list.

What the quote must separate

A BAL-40 quote that arrives as a single line per opening cannot be checked, and it cannot be value-engineered safely either. The quote should separate the window, the screen system, the glass upgrade, the certification pack and the delivery, because those are the five items that get cut when a project runs over budget — and four of them are compliance items. A buyer who can see the screen as a line item can also see what deleting it would do, which is usually the moment the conversation about BAL-40 becomes concrete.

The same logic applies to the fire evidence itself. If the test report is supplied as part of the order, it belongs in the quote as a deliverable rather than as a favour. The way a window price is built up, and which parts of it sit where, is set out in ROPO's breakdown of window and door prices; the payment instrument question is separate and is covered on the Trade Assurance page, which matters most on an import route.

Quote lineWhat it should containWhy it must be separateTypical failure if merged
Window unitSystem, size, opening type, hardwareIt is the only line that can be compared like for likeDifferent systems compared as if identical
Screen systemMesh material, aperture, frame fixing, test referenceIt is a compliance item, not an accessoryScreen deleted at value engineering
Glass upgradeMake-up, thickness, pane area against the reportPane limits are per report and easy to exceedLarge pane outside tested area
Certification packCertificate, test report, compliance statement, labelsIt is the deliverable the certifier filesPack assembled after handover, or not at all
Delivery and installation interfaceDelivery point, offloading, who installs to the detailWarranty boundary sits hereScreen or unit damaged and unclaimed

Separating the lines also fixes the comparison problem that makes BAL-40 pricing opaque. Two quotes for the same opening can differ by a screen system and a glass make-up and look like a 30% price gap on the same product, when they are really two different specifications. A buyer who insists on the five lines is comparing specifications, not totals.

Screens, shutters and the maintenance obligation

The screen is a maintained component, and the maintenance obligation survives handover. A BAL-40 house handed over with steel mesh screens needs the mesh, the fixings and the frame checked periodically, and any damaged section replaced with the same specification rather than with the nearest available mesh. Suppliers that publish the requirement also publish the care instruction, and a builder who passes that instruction to the owner has done more for the building's bushfire performance than a certificate on its own.

Shutters, where they are used, carry a heavier obligation: they need to be operable, they need clearance, and they need to be closed before the fire arrives rather than during it. That is the practical argument for a tested no-shutter system at BAL-FZ, and it is also why a BAL-40 specification should not assume that a shutter can be added later if the windows fail to perform. The BAL-29 compliant windows and doors guide covers the level below this one, and the bushfire suitability question answers the version of this that most buyers ask first.

State by state: where the BAL-40 work actually is

BAL-40 work is not evenly distributed, and the supplier list reflects that. The highest volumes sit where the vegetation and the topography combine: the peri-urban fringe of New South Wales, the Macedon Ranges and the Otways in Victoria, the Adelaide Hills and the Fleurieu in South Australia, the south-west and the Darling Scarp in Western Australia, and the urban interface in Queensland and Tasmania. The level is set by the site assessment, not by the state, so a coastal block with heavy fuel close by can be BAL-40 while an inland block in the same council area is BAL-19.

What changes by state is the administrative path rather than the physics. Some councils publish bushfire prone land maps and require the BAL assessment with the development application; others rely on the certifier to confirm it. A supplier whose service area covers the state is therefore useful in a specific way: it can tell you who in that state has assessed the site before, and it can produce the documentation in the form the local certifier expects. The Australian window programme collects the market-level detail for buyers working across states, and the custom aluminium windows for the rest of the schedule page is where the non-rated openings are normally priced.

State or territoryWhere BAL-40 assessments concentrateWhat the local supplier advantage looks like
New South WalesBlue Mountains, Hawkesbury, Central Coast hinterland, Hunter fringeSupply-only fabricators with certifier familiarity; NSW distribution coverage
VictoriaMacedon Ranges, Yarra Valley, Otways, Mornington Peninsula fringeIn-state manufacture and short remake loops
QueenslandSunshine Coast hinterland, Scenic Rim, Toowoomba fringeLabelled ranges and a single-state compliance chain
South AustraliaAdelaide Hills, Fleurieu Peninsula, Barossa fringeBranch coverage and local measure
Western AustraliaDarling Scarp, south-west towns, Perth hillsState fabricators, because national suppliers often exclude WA
TasmaniaHuon Valley, east coast, peri-urban HobartBranch or distributor presence, limited local manufacture
ACTUrban interface suburbsNational fabricators with ACT coverage

The table is a planning aid rather than a map: the authoritative source is the council's bushfire prone land map and the site assessment behind the permit. Its purpose here is narrower. A buyer who knows their state's pattern also knows which suppliers on this list can realistically attend a site, and that filters the ten faster than any ranking can.

About ROPO Windows

ROPO manufactures custom aluminium and uPVC windows and doors in Fuzhou, Fujian, China, and has supplied overseas builders, developers, fabricators and distributors for 16 years, with projects in more than 100 countries. The company sells factory-direct with a minimum order of one unit, publishes a 10-year warranty, and ships through Fuzhou and Xiamen. Certification covers AS 2047-2014 for Australia, NZS 4211 through CodeMark for New Zealand, and Miami-Dade for hurricane-rated markets, alongside AS 1288 glass selection. Payment can run through Trade Assurance, and every order passes a five-step quality process from incoming material to pre-shipment packing.

ROPO publishes this article and does not appear in the ten, for a reason stated earlier in plain terms: it does not publish an AS 1530.8.1 bushfire test, so it cannot claim a BAL-40 position, and a ranking that included it would be trading on the reader's assumption rather than on evidence. What it does publish is a structural and glass compliance set, a production process built to an opening schedule, and a documentation pack that travels with the container. On a bushfire project those are the parts of the job that sit outside the BAL-rated elevation — the leeward openings, the shed, the glazing that the permit does not assess.

What ROPO publishes, and what it does not

Published: the AS 2047-2014 certificate and its scope, glass selection under AS 1288, NZS 4211 through CodeMark, Miami-Dade for hurricane markets, the warranty statement, the quality process, the product ranges and the dealer programme. Not published, and not claimed here: an AS 1530.8.1 bushfire test, a BAL level, a price list, a fixed lead time in days or a landed cost for a specific port. Those last three are quoted per schedule, because they depend on opening sizes, glass make-up, container fill and freight at the time of booking.

The distinction is worth stating because the market often blurs it. A factory that publishes AS 2047 and Miami-Dade has done serious testing; neither test simulates a bushfire. A buyer who needs BAL-40 should ask for the fire report and accept a "no" as an answer, then split the schedule so the rated elevations go to a supplier who has one. The project aluminium windows range and the AS2047 aluminium windows page are where that split starts.

Where ROPO fits a bushfire project

The honest answer is on the elevations the permit does not rate, and on the repeatable part of a schedule where the design is locked. A buyer who has spent a month reading bal40 windows pages has usually learned the difference between a tested assembly and a catalogue claim by the time they reach this point, and that distinction is the one that decides which part of the schedule can travel. A BAL-40 house typically has one or two exposed elevations and several that are assessed at a lower level or not at all. The lower-level openings can be supplied to the same architectural language as the rated ones if the profiles and colours are matched early, which is a specification decision rather than a compliance one. ROPO's custom aluminium windows and doors range is the catalogue for that part of the job.

What ROPO does not do is measure, install or certify a BAL-40 elevation, and it does not have Australian factories, local stock or a local installation crew. Those belong to the local partners who handle the site end, and the split is normally documented in the order: factory for the units and the pack, partner for the measure, the install and the rectification. A project that tries to run the rated elevations through an import route without an AS 1530.8.1 report is taking a compliance risk that no price saving justifies.

Who ROPO is not the right supplier for

A BAL-40 or BAL-FZ elevation, a renovation with one window and a two-week deadline, a project that needs the supplier to measure and install, and any job where the design is still moving after the deposit. In each of those cases the local entries in this list are the better answer. The import route works when the schedule is repeatable, the specification is finished and the compliance evidence required is structural and glass rather than bushfire-specific.

A buyer who wants to test the route before committing can do it with a single unit, because the minimum order is one, and the process for that is set out in the guide to testing a supplier with a first order. The manufacturer profile and the factory and production base cover the company side, and the enquiry form is the shortest path to a schedule-based quote.

Specifying the non-rated elevations

A BAL-40 permit usually covers one or two elevations. The rest of the schedule can be supplied to the same profiles and colours from a factory, provided the specification is written once and the rated openings are carved out before pricing.

aluminium window catalogue

Custom Production Process

On an import route the process is the product, and on a bushfire project the process is also the compliance evidence. ROPO's production runs from the opening schedule rather than from a catalogue: profile cutting to the schedule, machining for hardware and drainage, frame assembly and corner crimping, glazing to the specified make-up, then hardware, sealing and inspection before packing. Each stage carries a check, and those checks are what the five-step quality process refers to when a buyer asks how a defect was caught before shipment rather than after installation.

What the process cannot do is manufacture a BAL-40 rating. The frame that comes off the line is the frame that was specified, and if the specification did not include a tested screen system and fire-rated glazing, the finished unit will not carry a BAL-40 claim no matter how well it is built. That is why the process section sits after the compliance sections in this article: the factory builds to the specification, so the specification has to be right before the cutting list is issued. The aluminium windows and doors range shows the profiles the schedule resolves to.

From drawing to cutting list

The buyer's schedule of openings becomes a cutting list, and the cutting list is where most specification errors are caught or missed. Elevation marks, opening direction, handing, sill height, glass make-up and screen provision all have to resolve to a line. A supplier that returns the cutting list for confirmation before extrusion gives the buyer a free review; a supplier that starts cutting without one transfers that risk to the site. ROPO confirms the schedule in writing before production, and the confirmed version is what the inspection is measured against.

Assembly, glazing and the screen interface

Assembly is where a system becomes a window: corner joints crimped and sealed, drainage paths kept clear, gaskets set without gaps, hardware fitted to the specified positions. On a bushfire specification, the same stage decides whether a screen can be fixed to the frame without fouling the sash or the lock, which is why the screen detail belongs in the production drawing rather than in a site instruction. Glazing follows the make-up on the schedule, and the glazing method is chosen for the frame rather than borrowed from another system. The thermally broken aluminium range is the one to read where a bushfire requirement overlaps an energy requirement, because the break, the gasket and the glass have to be specified together.

A lever handle and multi-point lock strip on a finished leaf at the factory. Hardware is where an operable sash is judged, and where a screen frame has to clear without fouling the lock.
A lever handle and multi-point lock strip on a finished leaf at the factory. Hardware is where an operable sash is judged, and where a screen frame has to clear without fouling the lock.

Inspection before packing, not after arrival

The five-step process ends with a pre-shipment inspection that checks dimensions against the confirmed schedule, operation of every sash and panel, glass condition, hardware function and finish. Where a buyer has nominated a third-party inspection, that inspection runs against the same schedule, so two sets of eyes are looking at the same document. A defect found here costs a rework; the same defect found on site costs a programme. Photographs of the inspected units, bundle by bundle, are the cheapest insurance either party can buy, and on a mixed schedule they are also the record of which opening went into which bundle.

Sliding sashes stacked by profile in the plant, rollers and interlock visible. The frame series and the sash stack decide whether a screen can be fitted later without remaking the opening.
Sliding sashes stacked by profile in the plant, rollers and interlock visible. The frame series and the sash stack decide whether a screen can be fitted later without remaking the opening.

Packaging and Shipping

A window that arrives undamaged is a packing decision made three weeks earlier, and on a bushfire order the packing has a second job: it protects the screens and the certification pack that make the units compliant. ROPO packs to the container plan rather than to the pallet: frames separated and edge-protected, sashes braced, glass protected at the corners, hardware bagged and labelled to the opening mark, and every bundle marked so it can be found without unpacking the load. The packaging guide shows the corner protection and the strapping pattern in practice.

Shipments leave through Fuzhou and Xiamen, and the documents a buyer needs — packing list, invoice, certificate pack — are issued together so the customs broker is not waiting on the factory. Who clears the goods at the Australian end is a choice the buyer makes, and it should be made before the container is booked rather than when it arrives. The full sequence, from minimum order to payment, is set out in the guide to importing windows and doors from China.

Bundle marking and the packing list

The packing list is the document that makes a container usable on site. Each bundle should carry the opening mark from the schedule, so a supervisor can send the right unit to the right elevation without opening everything. On a bushfire project the marking has an extra function: it ties each unit to the configuration that was tested, which is what a certifier needs when a sample is inspected after installation. ROPO labels to the opening mark, and the packing list is issued against the same list that production was measured against.

Two documents should travel with the load and are the ones most often missing: the packing list by opening mark, and the installation detail for each wall type. A supplier who can forward both without a week of emails is a supplier whose documentation is a by-product of production rather than a favour. The warranty terms set out what is covered and what the handling requirements are, and the product brochure is the quickest way to put the ranges in front of a client.

Site delivery and the first hour

The first hour on site decides most damage claims. Units should be offloaded to a hard, level surface, stored upright and never stacked flat, kept clear of traffic and protected from the weather until installation. Photograph the bundles before they are opened, count them against the packing list, and record any damaged corner before the crew starts moving them. On a BAL-40 order, check the screens in the same pass: a crushed screen frame is a compliance defect, not a cosmetic one, and it is far cheaper to replace before installation than after.

For a buyer assembling the whole pack, the shortest route is the aluminium window specification page, which collects the ranges, the glass options and the certificate references in one place. Buyers who want the wider market view before committing to a route can start from the national guide to window suppliers in Australia and the commercial guide to commercial aluminium window suppliers, both of which use the same evidence standard as this article.

Where the specification meets the schedule

A bushfire project usually splits into a rated elevation and a repeatable schedule. The factory side of that split is priced from the opening schedule, with glass make-up and screen provision written line by line.

AS2047 aluminium windows
Frequently asked questions
What does BAL 40 mean for a window?

BAL 40 is the second-highest bushfire attack level under AS 3959-2018, describing ember attack, burning debris and heat flux of 29 to 40 kW/m² with an increased likelihood of flame exposure. For a window it means a tested assembly, toughened glass, and external screening in steel mesh fixed to the frame.

Can I use standard windows in a BAL 40 area?

No, not on the rated elevation. The window has to be part of an assembly tested to AS 1530.8.1 at that level, with the screen the test assumed. A standard AS 2047 window meets the structural and water requirements but not the bushfire requirement, and a certifier will ask for the fire evidence separately.

Is the screen included in a BAL 40 window price?

It depends on the supplier, which is why the quote should list the screen as its own line. At BAL 40 the screen is a compliance item rather than an accessory, and deleting it to save cost removes the protection the rating depends on.

What is the difference between BAL 40 and BAL FZ?

BAL FZ assumes direct exposure to flames from the fire front with heat flux above 40 kW/m². Most suppliers protect that with a compliant bushfire shutter; a small number publish a tested system that works without one. BAL 40 does not assume direct flame contact, though it does assume flame exposure is more likely than at BAL 29.

Do imported windows meet BAL 40?

Only if the factory can produce an AS 1530.8.1 test report covering the frame, glass and screen combination, plus a compliance statement that matches the delivered units. An AS 2047 certificate and a Miami-Dade approval do not cover bushfire, and a factory that presents them as equivalent is not a safe specification source. That is the test to apply to any bal40 windows offer that arrives with a mixed certificate pack.

How many suppliers should a BAL 40 project shortlist?

Three is usually enough: one fabricator with a published BAL-40 range, one systems route through a licensed fabricator, and one specialist if the design includes louvres or a flame-zone edge. Fewer quotes on one specification beat many quotes on five.

Does a BAL 40 window need maintenance?

Yes. The screens, fixings and frame should be checked periodically, and damaged mesh replaced with the same specification rather than the nearest available product. A torn screen on a BAL 40 elevation is a compliance defect, not a cosmetic one.

Where does this national list stop and the city guides start?

This page covers suppliers who publish a BAL 40 position nationally or across several states. City guides cover local shortlists and delivery patterns that only make sense within one market. A project in a high-risk interface area should read both, and start with the council's bushfire prone land map.

Get A Quick Quote | Custom Windows and Doors
  • Quick selection quotation
  • Become ROPO Windows Partner
  • Australia Homeowner Quotation
  • NZ Homeowner Quotation
  • Ready to Share or Refer?
  • Interested in becoming a display home partner?
  • Want to Join Our Referral Program?
    • *Email
      *Full Name
      *Phone
    • *Email
      *Full Name
      *Phone
    • *Email
      *Full Name
      *Phone
    • *Email
      *Full Name
      *Phone
    • *Email
      *Full Name
      *Phone
    • *Email
      *Full Name
      *Phone
    • *Email
      *Full Name
      *Phone
Categories
Contact Person
Benson
Full Name:
Benson
Tel:

+86 591-87147106

Email:
sales@ropowindows.com
WhatsApp:
8615980112550
Address:
Address: No. 1 Phase, Tieling Technical And Economic Development Zone, Minhou County, Fuzhou City, Fujian Province, China